Conductor spacing calculator
Look up the minimum spacing between conductors for a given voltage from IPC-2221B Table 6-1, for every board location and coating case at once. Everything runs in your browser.
IPC-2221B Table 6-1, minimum spacing in mm
| Voltage (DC or AC peak) | B1 | B2 | B3 | B4 | A5 | A6 | A7 |
|---|---|---|---|---|---|---|---|
| 0–15 | 0.05 | 0.1 | 0.1 | 0.05 | 0.13 | 0.13 | 0.13 |
| 16–30 | 0.05 | 0.1 | 0.1 | 0.05 | 0.13 | 0.25 | 0.13 |
| 31–50 | 0.1 | 0.6 | 0.6 | 0.13 | 0.13 | 0.4 | 0.13 |
| 51–100 | 0.1 | 0.6 | 1.5 | 0.13 | 0.13 | 0.5 | 0.13 |
| 101–150 | 0.2 | 0.6 | 3.2 | 0.4 | 0.4 | 0.8 | 0.4 |
| 151–170 | 0.2 | 1.25 | 3.2 | 0.4 | 0.4 | 0.8 | 0.4 |
| 171–250 | 0.2 | 1.25 | 6.4 | 0.4 | 0.4 | 0.8 | 0.4 |
| 251–300 | 0.2 | 1.25 | 12.5 | 0.4 | 0.4 | 0.8 | 0.8 |
| 301–500 | 0.25 | 2.5 | 12.5 | 0.8 | 0.8 | 1.5 | 0.8 |
| > 500 | +0.0025/V | +0.005/V | +0.025/V | +0.00305/V | +0.00305/V | +0.00305/V | +0.00305/V |
B1 internal conductors · B2 external, uncoated, sea level to 3050 m · B3 external, uncoated, above 3050 m · B4 external with permanent polymer coating (any elevation) · A5 external with conformal coating over the assembly (any elevation) · A6 external component lead or termination, uncoated, sea level to 3050 m · A7 external component lead or termination with conformal coating (any elevation). Source: IPC-2221B, Generic Standard on Printed Board Design, section 6.3 and Table 6-1.
How the calculator reads the table
- The rows are whole-volt bands. A voltage between two bands (for example 15.5 V) uses the higher band.
- Above 500 V the table gives a spacing per volt. References apply it in two ways: adding the rate for every volt above 500 to the 301–500 V value, or multiplying the rate by the full voltage. Because this is a safety spacing, the calculator shows the larger of the two (for B2 and B3 they are equal). If your design is above 500 V, check the standard itself and the applicable safety standard.
- The values were transcribed carefully from the published table and checked against several independent reproductions, but always confirm them against your own copy of IPC-2221B before relying on them.
- mil values are converted from mm (1 mil = 0.0254 mm); the table itself is defined in mm.
Clearance, creepage and safety standards
IPC-2221B spacing is about reliable operation of the bare board. Product safety standards work differently: IEC 62368-1 (audio, video and IT equipment) and IEC 60664-1 (insulation coordination for low-voltage equipment) set separate clearance (through air) and creepage (along the surface) distances that depend on working voltage, overvoltage category, pollution degree, material group and the kind of insulation (functional, basic or reinforced). Mains-connected and safety-isolating designs often need far more spacing than this table. This tool is not a safety certification and does not replace an evaluation against the standard that applies to your product.
FAQ
Which category should I use for a normal outer layer?
B2 for bare outer-layer conductors on a board used below 3050 m. Solder mask alone is not usually treated as a permanent polymer coating for B4 purposes unless your design specification says so.
Why are the component lead values larger?
Exposed leads and solder joints cannot be covered by the board's coating and collect contamination, so A6 and A7 apply to them even when the tracks are covered.
Should I enter RMS or peak voltage?
Peak. The table is defined for DC or AC peak voltage between conductors. For a 230 V RMS sine wave that is about 325 V, before any transients.
Can my fab build smaller spacing than this?
Often yes, the manufacturing minimum is usually 0.1 mm or less. This table is about electrical spacing for the voltage, not about what can be etched.