Most first-time fab rejections we see are not exotic. They are vias: a drill too small for the fab’s standard process, or a pad too small around it. Both are easy to avoid once you know what the fab is protecting against.
What the annular ring is
The annular ring is the copper left around a plated hole:
A 0.6 mm pad with a 0.3 mm drill has a 0.15 mm ring. That is the designed ring. The ring on the finished board is smaller, because the drill never lands exactly in the middle of the pad.
Reason 1: the drill wanders
Holes are drilled through a stack of panels after the inner layers have been imaged, etched and laminated. Every step adds a little positional error: film or direct-imaging registration, material movement during lamination, drill-bit deflection. The fab budgets for this total error when it sets its minimum ring. If the budget exceeds your designed ring, the drill can break out of the pad — the hole cuts through the edge of the copper.
IPC-6012 sets what is acceptable on the finished board. For the common Class 2, a limited breakout on external layers is tolerated (up to 90° of the circumference); Class 3 boards must keep a minimum external ring of 50 µm all the way round. Fabs therefore ask for a designed ring well above those numbers so that the finished board still passes.
Reason 2: finished size is not drilled size
For plated holes, KiCad’s drill value is normally the finished hole size. The fab drills larger to leave room for the copper plated onto the barrel wall — typically on the order of 0.1 mm larger in diameter, depending on the process. So a 0.3 mm finished via is drilled with a bit of about 0.4 mm, and the ring the fab sees is smaller than the one you drew.
This is also why the smallest mechanical drill a fab offers on its standard process is the number that matters for vias. Going below it usually means a different, more expensive process class, or laser-drilled microvias.
Reason 3: aspect ratio
Plating chemistry has to flow through the hole. The ratio of board thickness to drill diameter — the aspect ratio — limits how small a through-hole can be for a given board. A 0.2 mm drill through a 1.6 mm board is an 8:1 aspect ratio, which many standard processes do not offer, while the same drill through a 0.8 mm board is 4:1 and routine. When you shrink vias, check the board thickness at the same time.
Choosing via sizes that pass first time
| Use | Typical finished drill / pad | Designed ring | Notes |
|---|---|---|---|
| General signal and stitching vias | 0.3 / 0.6 mm | 0.15 mm | Accepted by essentially every standard process. |
| Denser routing | 0.25 / 0.5 mm | 0.125 mm | Check the fab’s minimum ring; some ask for 0.13 mm or more. |
| Fine-pitch BGA escape | 0.2 / 0.45 mm or smaller | ≈ 0.12 mm | Often a premium process; watch the aspect ratio. |
| Power vias | 0.4–0.5 / 0.8–1.0 mm | 0.2–0.25 mm | Several in parallel beat one large via for current and inductance. |
These are starting points, not guarantees: capabilities differ between fabs, between their standard and advanced services, and between 2-layer and multilayer builds. Always check the fab’s current capability table.
How we check it
The DFM pre-check in the 3D Studio and on the order form measures every via and plated pad against the capability table of the fab you choose, and flags drills below the minimum and rings below the minimum with the measured value and the limit, for example “Via 0.450 mm/0.200 mm: ring 0.125 mm < 0.130 mm”. Each finding is marked on the 3D model so you can fly to it. The profiles are indicative standard-service values; the fab’s own CAM check is the final word.
During routing we use via sizes from your net classes, and when we have a choice we pick the largest via the local density allows. It costs nothing and buys margin on every one of the rules above.